Kia Cadenza: Airbag Module / Curtain Airbag (CAB) Module Repair procedures

Kia Cadenza YG 2016-2025 Service Manual / Restraint / Airbag Module / Curtain Airbag (CAB) Module Repair procedures

Removal
1.
Disconnect the battery negative cable and wait for at least thirty seconds before beginning work.
2.
Remove the roof trim.
(Refer to Body - "Roof trim assembly")
3.
Disconnect the curtain airbag harness connector (A).

4.
After loosening the mounting bolts and nuts remove the curtain airbag.
Installation
1.
Remove the ignition key from the vehicle.
2.
Disconnect the battery negative cable and wait for at least thirty seconds.
3.
Tighten the curtain airbag mounting bolts and nuts.

Tightening torque
Bolts : 9.8 ~ 14.7 N.m (1.0 ~ 1.5 kgf.m, 7.2 ~ 10.8 lb-ft)
Nuts : 7.8 ~ 11.8 N.m (0.8 ~ 1.2 kgf.m, 5.8 ~ 8.7 lb-ft)

   
Never twist the airbag module when installing it. If the module is twisted, airbag module may operate abnormally.
4.
Connect the curtain airbag connector.
5.
Install the roof trim.
(Refer to Body - "Roof trim assembly")
6.
Reconnect the battery negative cable.
7.
After installing the curtain airbag (CAB), confirm proper system operation:
Turn the ignition switch ON; the SRS indicator light should be turned on for about six seconds and then go off.
Curtain Airbag (CAB) Module Components and Components Location
Components ...

Airbag Module Disposal Description and Operation
Airbag Disposal Special tool required Deployment tool 0957A-34100A Before scrapping any airbags or side airbags (including those in a whole vehicle to be scrapped), the airbags or side airba ...

Other information:

Kia Cadenza YG 2016-2025 Service Manual: Electric Parking Brake (EPB) Repair procedures


Removal 1. Turn ignition OFF and disconnect the negative (-) battery cable. 2. Remove the crash pad lower panel and reinforcing panel (A). (Refer to the Body group - “Crash pad”) 3. EPB control unit mounting nuts (B) and then remove EPB control unit. Tighten torque: 3.9 ~ 5.9 N. ...

Kia Cadenza YG 2016-2025 Service Manual: Body Control Module (BCM) Specifications


Specifications ItemsSpecificationsRated voltageDC 12VOperating voltageDC 9 ~ 16VOperating temperature-22°F ~ 167°F (-30°C ~ 75°C)Dark currentKeyless type : Max. 4.5mAStandard : Max. 3.0mA ...