| Specification |
| Pressure [KPa (kgf/cm², psi)] | Output Voltage (V) |
| 50 (0.51, 7.3) | 0.3 |
| 600 (6.12, 87.0) | 2.5 |
| 1100 (11.2, 159.5) | 4.5 |
| 1200 (12.2, 174.0) | 5 |

Description The fuel pressure sensor (FPS) is installed on the top of the low pressure fuel pump and measures the pressure in the low pressure fuel line.
Removal In case of removing the high pressure fuel pump, high pressure fuel pipe, delivery pipe, and injector, there may be injury caused by leakage of the high pressure fuel.
Description 1. The function of cluster ion generator is cleaning air by sterilizing and dissolving of air conditioner. 2. The function of cluster ion generator is controlling mold caused by stench of air conditioner and external inflow of air.
Inspection 1. Ignition "ON" 2. Manually operate the control switch and measure the voltage of blower motor. 3. Select the control switch to raise voltage until high speed. Specification FanMotor VoltageManualFirst speed3.8 ±0.5VSecond speed5.