| Specification |
| A/F Ratio (λ) | Output Voltage(V) |
| RICH | Min. 0.8 |
| LEAN | Max. 0.1 |
| Item | Specification |
| Heater Resistance (Ω) | 3.3 ~ 4.1[20°C(68°F)] |
Description Heated Oxygen Sensor (HO2S) consists of the zirconium and the alumina and is installed on upstream and downstream of the Warm-up Catalytic Converter (WCC).
Troubleshooting Problem Symptoms Table Before replacing or repairing air conditioning components, first determine if the malfunction is due to the refrigerant charge, air flow or compressor. Use the table below to help you find the cause of the problem.
Inspection 1. Ignition "OFF” 2. Disconnect the connector of mode control actuator. 3. Verify that the mode control actuator operates to the defrost mode when connecting 12V to the terminal 3and grounding terminal 7. 4. Verify that the mode control actuator operates to the vent mode when connecting in the reverse.