| Special Service Tools |
| Tool(Number and Name) | Illustration | Use |
| Deployment tool 0957A-34100A |
| Airbag deployment tool. |
| Deployment adapter 0957A-3F100 |
| Use with deployment tool. (SAB) |
| Deployment adapter 0957A-3Q100 |
| Use with deployment tool. (DAB, PAB, CAB, BPT, EFD) |
| Dummy 0957A-38200 |
| Simulator to check the resistance of each wiring harness. |
| Dummy adapter 0957A-3F000 |
| Use with dummy (SAB) |
| Dummy adapter 0957A-2G000 |
| Use with dummy (DAB, PAB, CAB, BPT, EFD) |
Warning Lamp Activation Warning Lamp Behavior after Ignition On As soon as the operating voltage is applied to the SRSCM ignition input, the SRSCM activates the warning lamp for a LED lamp check.
Component Replacement After Deployment Before doing any SRS repairs, use the GDS to check for DTCs. Refer to the Diagnostic Trouble Code list for repairing of the related DTCs.
Inspection 1. Press the OFF switch more then 4 times within 2 seconds while pressing the MODE switch. DisplayFail description00Normal50Cluster ionizer fault * Diagnostic procedure refer to DTC code. Replacement 1. Disconnect the negative (-) battery terminal.
Inspection 1. Ignition "OFF” 2. Disconnect the connector of mode control actuator. 3. Verify that the mode control actuator operates to the defrost mode when connecting 12V to the terminal 3and grounding terminal 7. 4. Verify that the mode control actuator operates to the vent mode when connecting in the reverse.