Kia Cadenza: Lubrication System / Oil Level Gauge & Pipe Repair procedures

Kia Cadenza YG 2016-2025 Service Manual / Engine Mechanical System / Lubrication System / Oil Level Gauge & Pipe Repair procedures

Removal and Installation
1.
Remove the oil level gauge rod (A) and the oil level gauge (B).

Tightening torque:
18.6 ~ 22.6N.m (1.9 ~ 2.3kgf.m, 13.7 ~ 16.6lb-ft)

   
When installing, apply engine oil to the O-ring and take care the O-ring not to be damaged.
Always use a new O-ring.
2.
Installation is in the reverse order of removal.
Oil Level Gauge & Pipe Components and Components Location
Components 1. Oil level gauge2. Oil level gauge pipe3. O-ring ...

Intake And Exhaust System
...

Other information:

Kia Cadenza YG 2016-2025 Service Manual: Timing Chain Components and Components Location


Components 1. Oil pump chain cover2. Oil pump sprocket3. Oil pump chain 4. Oil pump tensioner assembly5. Crankshaft oil pump sprocket6. Crankshaft RH chain sprocket7. RH Timing chain auto tensioner8. RH Timing chain tensioner arm9. RH Timing chain 10. RH Timing chain cam to cam guide11. RH Timi ...

Kia Cadenza YG 2016-2025 Service Manual: Crankshaft Position Sensor (CKPS) Repair procedures


Inspection 1. Check the signal waveform of the CMPS and CKPS using the GDS. Specification: Refer to “Wave Form” Removal 1. Turn the ignition switch OFF and disconnect the battery negative (-) cable. 2. Remove the air cleaner assembly. (Refer to Engine Mechanical System - "A ...