Removal 1. Disconnect the negative (-) battery terminal. 2. Remove the crash pad lower panel (A). 3. Remove the Reinforcing panel after loosening the mounting bolt and nut.
Specifications IMS Electrical System ItemSpecificationRating voltageDC 12VOperating voltageDC 9V ~ 16VOperating temperature-30°C ~ +80°CMaintaining temperature-40°C ~ +85°CMax, humid95%Consumption currentMAX 700mADark currentBelow 2mA Motor Electrical System ItemSpecificationRating voltage13.
Removal 1. If the compressor is marginally operable, run the engine at idle speed, and let the air conditioning work for a few minutes, then shut the engine off. 2. Disconnect the negative cable from the battery. 3. Recover the refrigerant with a recovery/charging station.
Inspection 1. Press the OFF switch more then 4 times within 2 seconds while pressing the MODE switch. DisplayFail description00Normal23Auto defog sensor OPEN24Auto defog sensor SHORT43Defog door potentiometer OPEN/SHORT44Defog door potentiometer * Diagnostic procedure refer to DTC code.